求教,ansys接触分析出现的警告提示?最后紫色线在青色线上方.算是收敛了吧
来源:学生作业帮 编辑:百度作业网作业帮 分类:综合作业 时间:2024/07/05 07:12:16
求教,ansys接触分析出现的警告提示?最后紫色线在青色线上方.算是收敛了吧
1,Volume 85 is being meshed entirely with SOLID45 tetrahedra, which can be much less accurate than bricks. Use quadratic (10-node) tetrahedra if available.
2, Shape testing revealed that 7 of the 1008955 new or modified elements violate shape warning limits. To review test results, please see the output file
or issue the CHECK command.
3, Unselected line 570.
4, PRETS179 element maintains its original orientation in a large deformation analysis.
5, Meshes made up of 10 percent or more of SOLID45 tetrahedra are not recommended.
6, Previous testing revealed that 7 of the 1291273 selected elements violate shape warning limits. To review warning messages, please see the output or
error file, or issue the CHECK command.
7, Some target elements on target surface specified by real constant set 3 belong to symmetric contact (e.g.3), some do not.
8,There are 106 small equation solver pivot terms.
9,Contact element 1157861 (real ID 7) has too much penetration 0.924635124 related to target element 1261698.
10, Solution not converged at time 1 (load step 1 substep 1). Run terminated.
11, The unconverged solution (identified as time 1 substep 999999) is output for analysis debug purposes. Results should not be used for any other purpose.
求教高手指点,我这些整个运行下来的错误,哪些是应该修改的,哪些是正常的.怎么修改?
1,Volume 85 is being meshed entirely with SOLID45 tetrahedra, which can be much less accurate than bricks. Use quadratic (10-node) tetrahedra if available.
2, Shape testing revealed that 7 of the 1008955 new or modified elements violate shape warning limits. To review test results, please see the output file
or issue the CHECK command.
3, Unselected line 570.
4, PRETS179 element maintains its original orientation in a large deformation analysis.
5, Meshes made up of 10 percent or more of SOLID45 tetrahedra are not recommended.
6, Previous testing revealed that 7 of the 1291273 selected elements violate shape warning limits. To review warning messages, please see the output or
error file, or issue the CHECK command.
7, Some target elements on target surface specified by real constant set 3 belong to symmetric contact (e.g.3), some do not.
8,There are 106 small equation solver pivot terms.
9,Contact element 1157861 (real ID 7) has too much penetration 0.924635124 related to target element 1261698.
10, Solution not converged at time 1 (load step 1 substep 1). Run terminated.
11, The unconverged solution (identified as time 1 substep 999999) is output for analysis debug purposes. Results should not be used for any other purpose.
求教高手指点,我这些整个运行下来的错误,哪些是应该修改的,哪些是正常的.怎么修改?
Solution not converged ,这表示没有收敛,你的计算肯定是以弹出error对话框终止的.你这问题,重做,建议,这么多警告和error,问题解的可靠性太差了.Results should not be used for any other purpose.告诉你不建议使用问题的结果.警告1表示单元精度不够,换单元类型;警告2表示网格划分不满足要求,重新划分网格;警告3,有一条线没选上,不知道对问题有多大影响;其他慢慢分析吧,反正建议不要敷衍过去,好好看看有限元,这结果不太可靠.
求教,ansys接触分析出现的警告提示?最后紫色线在青色线上方.算是收敛了吧
ansys接触分析时,总是出现以下的警告:
ANSYS接触分析时出现警告,
ansys workbench 14.5做接触分析出现警告,
在ansys中有关非线性计算时,如何设置收敛值,计算时出现的警告,如何处理呢
ansys做接触分析,一直在计算,是不是计算不收敛啊,半天了已经
ansys模态分析.最后求解时出现下面的警告:Element 1 has an undefined node numbe
ansys接触分析ansys接触分析是要在两个重合的线上才能做吗?把接触位置的线合并成一根线后,还能用Target和Co
ANSYS在做静力分析时,出现了这个错误提示:
如下的三个图是在ansys静力分析,载荷施加和求解过程中出现的,当最后点击yes后,ansys自动退出了,
ANSYS分析接触分析,经常出现不收敛,好像有很多参数可以调,比如求解控制参数,还有就是接触单元属性参数
ansys接触分析的问题